Fluid Testing:
PropTester®, Inc.
fluid specialists are on location (onshore or
offshore) prior to the stimulation treatment to
perform water analysis, identify chemical additives,
audit chemical & base fluid inventories, evaluate
chemical compatibilities, determine polymer
hydration rates, verify cross-link times, and
calibrate chemical feed pumps. The job design, a
pre-frac material balance, and treatment schedule
are reviewed with service company personnel and the
operator representative. Chemical inventories are
documented during each stage and the final mass
balance is calculated. Proppant transportation &
delivery records are also recorded as part of the
fluid service. All data is maintained centrally by
PropTester®, Inc. for future comparison or application, as
needed.
PropTester®, Inc. can determine
the quality of your water and its scaling
tendencies.
A water analysis can be partial or complete
depending on requirements. When a complete water
analysis is needed, then one is able to complete a
Stiff plot which reflects a fingerprint of that
particular water sample. The fingerprint is composed
of complementary anions & cations, representing
water composition. Test parameters may include as
follows:
-
Specific gravity
-
pH
-
Alkalinity (bicarbonate,
carbonate, & hydroxide)
-
Chloride
-
Calcium
-
Magnesium
-
Total hardness
-
Iron, total
-
Sulfide
-
Sulfate
-
Total dissolved solids
-
Sodium
-
Resistivity
-
Bacteria testing
| |
Let
PropTester®, Inc. be your eyes and
ears during the stimulation
treatment. We work closely with the
service company to document issues
critical to job execution such as:
- Physical inventory (Final /
Initial)
- Bucket testing or checking
accuracy of LAS pumps
- Pre-frac water analysis
- Hydration rate / viscosity
yield with a rotational
viscometer
- Measurement of cross-link
time where applicable
- Confirmation of breaker
types, loadings, & scheduling
- Evaluation of clean & dirty
samples during the frac job
- Mass balance calculation
- Correlation of actual
execution with job design
- HCl acid titration when
applicable
|
Base Laboratory Fluid Testing:
PropTester®, Inc. experts have extensive, hands on, field experience
to determine what fracturing fluid is best suited for your specific field
application. Pre-job fluid rheology profiles and breaker schedules can be
obtained with recommended formulations using a high pressure / high temperature
rheometer. Customize your tests to suit your needs. Shear rates from 1 to 1000
sec-1, up to 500˚F and 2000 psi. All data is maintained centrally by PropTester®, Inc.
for future comparison or application, as needed
Regained Fluid Testing:
Fracturing fluid can do 90% damage to a proppant pack as it is
being placed in the formation. Maximize production by minimizing fluid damage.
PropTester®, Inc. can maximize your breaker schedule and use the Chandler 5500 to make
sure you still have the rheology to place the proppant.
|